To obtain optimum performance from your Footcontroller, please read this guide before its use.
Specifications:
Communication
MIDI, Midi channel 0 (default)
Selector Switches
Indicator LEDs for preset display
and tap tempo
Expression Pedal
Passive volume control type,
50k – 1M ohm impedance
Power Requirements
Supplied via MIDI cable when used
with Crate DX amplifiers
Dimensions
2.25"H x 15"W x 4"D
• Specifications and information subject to change without notice •
www.crateamps.com
©2000 SLM Electronics, Inc. • A Division of St. Louis Music, Inc.
1400 Ferguson Avenue • St. Louis, MO 63133
Additional Technical Information:
The DXJFC communicates to the DX amplifier via MIDI (Musical Instrument
Digital Interface). Communication is on MIDI channel 0 by default, since the DX
amplifier operates in "omni/poly" mode.
Presets are changed by standard MIDI program change messages. The MIDI
message value can range from 0 to 9.
The Tap function defaults to MIDI controller #80. Value decimal 127 (hex 7F)
is sent when the tap is pressed, zero is sent when it is released.
The expression pedal defaults to controller #11 using single byte controller val-
ues. Pedal assignments are communicated to the DX amplifier via a MIDI "sys-
tem exclusive" (aka sysex) message. The following chart shows the sysex mes-
sage format (in hexidecimal) after the System Exclusive status byte.
00, 01, 28 SLME sysex ID code
SLME packet type
packet number (zero)
packet data byte count
DXJFC product ID
00, kk knob ID (2 bytes) "kk" = knob ID
00, 01 action ID (2 bytes)
checksum "cc" = calculated checksum
end of sysex
Our app is now available on Google Play